Product Details
Power Source and Run Time
Rechargeable slim-extended lithium-ion battery
- (18 hours typical @ 20°C) without pump
Rechargeable lithium-ion battery
- (12 hours typical @ 20°C) without pump
Rechargeable extended-range lithium-ion battery
- (20 hours typical @ 20°C) without pump
- (12 hours typical @ 20°C) with pump
Replaceable AAA alkaline battery
- (8 hours typical @ 20°C) without pump
- (4 hours typical @ 20°C) with pump
Temperature Range
-20 °C to 50 °C (-4 °F to 122 °F) **
Humidity Range
15-95% non-condensing (continuous)
Sensors and Measuring Ranges
- Combustible gases: 0-100% LEL in 1% increments
- Methane (CH4): 0-5% of vol in 0.01% increments
- Oxygen (O2): 0-30% of vol in 0.1% increments
- Carbon monoxide (CO): 0-1,000 ppm in 1 ppm increments
- Hydrogen sulfide (H2S): 0-500 ppm in 0.1 ppm increments
- Nitrogen dioxide (NO2): 0-150 ppm in 0.1 ppm increments
- Sulfur dioxide (SO2): 0-150 ppm in 0.1 ppm increments